Specifications
Tenney Testing Chambers
|
Tenney T2 Test Chamber Specifications
| Model |
T2RC |
T2C |
| Workspace |
W |
17(432) |
17(432) |
D |
13(330) |
13(330) |
H |
16(406) |
16(406) |
| Exterior |
W |
26.5(673) |
26.5(673) |
D |
23(584) |
23(584) |
H |
69 (1753) |
69 (1753) |
Temperature & Humidity |
| Low |
C |
-75 |
-75 |
| High |
C |
+200 |
+200 |
| Change Rates in Minutes |
|
Ambient to °C Chamber Empty |
200° |
90 |
90 |
150° |
40 |
40 |
| 100° |
25 |
25 |
93° |
17 |
17 |
65° |
9 |
9 |
2° |
5 |
5 |
-7° |
7 |
7 |
-12° |
10 |
10 |
-40° |
30 |
30 |
-54° |
45 |
45 |
| |
-65° |
70 |
70 |
| |
-73° |
100 |
100 |
| |
-75° |
Ultimate |
Ultimate |
| Utilities, etc |
| Refrigeration |
(2) 1/2) HP+ 1/2 HP |
(2) 1/2) HP + 1/2 HP |
| Heater Capacity |
500W |
500W |
| Humidifier |
W |
500 |
— |
| |
GPH |
.15 |
— |
| AMPS @ 115V. 1Ø |
18 |
18 |
| AMPS Fuse |
20 |
20 |
| Unit Weight |
LBS/KG |
350/158 |
350/158 |
Humidity capablility: 20% to 98% RH in the dry bulb range of +20°C to 85°C as
limitied by a 3° dewpoint. Test data based on 24°C ambient, sea level, 60Hz.
On 50 Hz or higher than 24°C ambient, performance may be reduced. Consult
factory regarding any special cooling requirements. CFC-free refrigerants are
used exclusively on al Tenney chambers.
|
|
|
|